Skip to content
runonprem

Power & electricity

Home server Build Planner

Plan a home server from its parts: see the idle and load power, what it costs to run per year at your electricity price, the parts total and whether the drives and UPS fit. Systems, graphics cards and UPS come from the hardware database; every value stays editable.

W
W
USD
W
W
W
W
%
h
USD
Idle power
23 W
Load power
54 W
Average power
26.1 W
Energy per year
229 kWh
Electricity per year
$34.30
Parts total
$750.00
Parts + 3 years of power
$852.89
Parts + 5 years of power
$921.48

How to use it

  1. Pick a base system from the database or keep “Custom build”, then enter its idle and load power — ideally measured at the wall with a plug-in meter.
  2. Add hard drives and M.2 SSDs with their power per drive from the datasheet (the defaults are typical values, not a specific model).
  3. Add a graphics card and a UPS if you plan them; the GPU load defaults to its rated board power.
  4. Choose an official electricity price or type your own, and read the yearly cost, totals and checks on the right.

Formula and method

idle W    = Σ (idle W of each part × quantity)
load W    = Σ (load W of each part × quantity)
average W = idle W × (1 − time at load) + load W × time at load
kWh/year  = average W × hours per day × 365 ÷ 1000
cost/year = kWh/year × price per kWh
UPS check : UPS watts ≥ load W × 1.25

Worked example

A system idling at 12 W (35 W load) with two hard drives at 5 W idle / 7 W active and one SSD at 1 W / 5 W idles at 12 + 2 × 5 + 1 = 23 W and peaks at 35 + 2 × 7 + 5 = 54 W. At load 10 % of the time it averages 23 × 0.9 + 54 × 0.1 = 26.1 W, i.e. 26.1 × 24 × 365 ÷ 1000 = 228.6 kWh a year — 34.30 at 0.15 per kWh. Parts of 300 + 2 × 180 + 90 = 750 plus five years of power make 750 + 5 × 34.295 = 921.48.

FAQ

Why are the drive power defaults not from the database?

Drive power depends on the exact model and workload. The defaults (5 W idle / 7 W active for a 3.5-inch drive, 1 W / 5 W for an NVMe SSD) are typical datasheet values; replace them with your drive’s datasheet figures.

Is the CPU TDP my server’s power draw?

No. TDP is a thermal rating of the processor under sustained load. A complete low-power system often idles far below it, while the wall draw under load includes everything else in the box. Use measured values for the most accurate cost.

How big should the UPS be?

The planner checks that the UPS watt rating covers the load plus 25 % headroom. Use the UPS runtime calculator to see how long its batteries last.

Related tools

Formulas reviewed November 28, 2026 by Novian · runs entirely in your browser · methodology