Power & electricity
Home server Build Planner
Plan a home server from its parts: see the idle and load power, what it costs to run per year at your electricity price, the parts total and whether the drives and UPS fit. Systems, graphics cards and UPS come from the hardware database; every value stays editable.
- Idle power
- 23 W
- Load power
- 54 W
- Average power
- 26.1 W
- Energy per year
- 229 kWh
- Electricity per year
- $34.30
- Parts total
- $750.00
- Parts + 3 years of power
- $852.89
- Parts + 5 years of power
- $921.48
How to use it
- Pick a base system from the database or keep “Custom build”, then enter its idle and load power — ideally measured at the wall with a plug-in meter.
- Add hard drives and M.2 SSDs with their power per drive from the datasheet (the defaults are typical values, not a specific model).
- Add a graphics card and a UPS if you plan them; the GPU load defaults to its rated board power.
- Choose an official electricity price or type your own, and read the yearly cost, totals and checks on the right.
Formula and method
idle W = Σ (idle W of each part × quantity) load W = Σ (load W of each part × quantity) average W = idle W × (1 − time at load) + load W × time at load kWh/year = average W × hours per day × 365 ÷ 1000 cost/year = kWh/year × price per kWh UPS check : UPS watts ≥ load W × 1.25
- Rated power (TDP, board power) is a manufacturer figure for the chip or card under sustained load; a whole system at the wall also includes the power supply’s losses, fans and drives. Measure when you can.
- Bay and M.2 slot checks use the counts of the selected system in the database. Custom builds are not checked.
- Part prices are yours to enter; runonprem does not track retail prices yet.
Worked example
A system idling at 12 W (35 W load) with two hard drives at 5 W idle / 7 W active and one SSD at 1 W / 5 W idles at 12 + 2 × 5 + 1 = 23 W and peaks at 35 + 2 × 7 + 5 = 54 W. At load 10 % of the time it averages 23 × 0.9 + 54 × 0.1 = 26.1 W, i.e. 26.1 × 24 × 365 ÷ 1000 = 228.6 kWh a year — 34.30 at 0.15 per kWh. Parts of 300 + 2 × 180 + 90 = 750 plus five years of power make 750 + 5 × 34.295 = 921.48.
FAQ
Why are the drive power defaults not from the database?
Drive power depends on the exact model and workload. The defaults (5 W idle / 7 W active for a 3.5-inch drive, 1 W / 5 W for an NVMe SSD) are typical datasheet values; replace them with your drive’s datasheet figures.
Is the CPU TDP my server’s power draw?
No. TDP is a thermal rating of the processor under sustained load. A complete low-power system often idles far below it, while the wall draw under load includes everything else in the box. Use measured values for the most accurate cost.
How big should the UPS be?
The planner checks that the UPS watt rating covers the load plus 25 % headroom. Use the UPS runtime calculator to see how long its batteries last.
Related tools
- Power consumption & electricity cost calculator — Turn a server’s idle and load watts into kWh and electricity cost per day, month and year, with official prices per country and US state.
- UPS runtime & sizing calculator — Estimate how long a UPS keeps your homelab running and which VA/W rating to buy for your load.
- RAID & ZFS capacity calculator — Usable capacity, efficiency and fault tolerance for RAID 0/1/5/6/10, ZFS mirrors and RAIDZ1/2/3, in TB and TiB.
Formulas reviewed November 28, 2026 by Novian · runs entirely in your browser · methodology